Construction
(1) Conductors
Number of conductors: 2 and 3.
The conductors comply with the requirements given in IEC 60228 for class 5.
(2) Insulation
The insulation is polyvinyl chloride compound of type PVC/D applied around each conductor.
(3) Assembly of cores
Circular cord: the cores are twisted together.
Flat cord: the cores are laid parallel.
(4) Sheath
The sheath is polyvinyl chloride compound of type PVC/ST5 applied around the cores.
The sheath fills the spaces between the cores, thus forming a filling, but it does not adhere to the cores. The assembly of cores is surrounded by a separator, which does not adhere to the cores.
The assembly of circular cords has a practically circular cross-section.
Technical Performance
Maximum conductor temperature in normal use: 70°C
The use of the cable type 60227 IEC 52 complies with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.
Parameter Table
| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| Number and nominal cross-sectional area of conductors mm² |
Thickness of insulation | Thickness of sheath | Mean overall dimensions | Minimum insulation resistance at 70°C MΩ·km |
|
| Specified value mm |
Specified value mm |
Lower limit mm |
Upper limit mm |
||
| 2 × 0.5 | 0.5 | 0.6 | 4.6 or 3.0 × 4.9 |
5.9 or 3.7 × 5.9 |
0.012 |
| 2 × 0.75 | 0.5 | 0.6 | 4.9 or 3.2 × 5.2 |
6.3 or 3.8 × 6.3 |
0.010 |
| 3 × 0.5 | 0.5 | 0.6 | 4.9 | 6.3 | 0.012 |
| 3 × 0.75 | 0.5 | 0.6 | 5.2 | 6.7 | 0.010 |
Advantages
(1) Consistent Product Quality
We achieve superior product consistency through:
- Premium-grade material procurement
- State-of-the-art production methodologies
- Multi-layered quality verification process:
- Incoming material analysis
- Production phase monitoring
- Intermediate product validation
- Final output certification
- Comprehensive digital documentation
- Physical sample preservation
- Complete batch traceability
This systematic approach guarantees products that consistently meet and exceed customer expectations.
(2) Industry-Leading Delivery Speed
Our supply chain advantages include:
- Extensive finished goods inventory
- Strategic work-in-progress reserves
- Adaptive manufacturing protocols
- Real-time production scheduling
These capabilities enable us to:
- Accommodate emergency orders
- Handle volume fluctuations
- Meet critical deadlines
- Maintain quality benchmarks
(3) Tailored Customization Services
Our customization framework features:
- Specialized project coordination
- Cross-functional expert teams:
- Research & Development
- Technical Sales
- Production Engineering
- Quality Assurance
- Customer Support
- Integrated workflow management
- Tailored technical specifications
This structure delivers precision-engineered solutions aligned with each client's unique operational requirements.
Frequently Asked Questions (FAQ)
The cable complies with the requirements given in IEC 60228 for class 5 conductors, and its application complies with IEC 62440 for the safe use of electric cables with a rated voltage not exceeding 450/750 V.
The insulation is made of a polyvinyl chloride compound of type PVC/D applied around each conductor. The outer sheath is constructed from a polyvinyl chloride compound of type PVC/ST5.
The maximum conductor temperature for these cables under normal operating conditions is 70°C.
For circular cords, the cores are twisted together to form a practically circular cross-section. For flat cords, the cores are laid parallel to each other.
We implement a multi-layered quality verification process including incoming material analysis, production phase monitoring, intermediate validation, final certification, digital documentation, and complete batch traceability.
Yes, we offer tailored customization services supported by specialized project coordinators and a cross-functional team of R&D, Technical Sales, Production Engineering, Quality Assurance, and Customer Support.