Introducing our high-quality electrical cables, designated with the code 60227 IEC 10, manufactured in compliance with the IEC 60227-4 standards. Our cables are rated for voltages of 300/500 V, ensuring reliability and safety in various applications. As a leading factory and supplier in China, we are committed to providing superior products that meet international standards. Trust us to deliver the best electrical solutions for your needs.

    Construction

    • (1) Conductors

      Number of conductors: 2, 3, 4 or 5

      The conductors comply with the requirements of IEC 60228:

      - class 1 for solid conductors;

      - class 2 for stranded conductors.

    • (2) Insulation

      The insulation is polyvinyl chloride compound of type PVC/C applied around each conductor.

    • (3) Assembly of cores

      The cores are twisted together.

    • (4) Inner covering

      The twisted cores are covered by an extruded inner covering consisting of an unvulcanized rubber or plastic compound.

      It is possible to separate the cores easily.

    • (5) Sheath

      The sheath is polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.

      The sheath fit closely and it is possible to remove it without damage to the inner covering.

    Technical Performance

    Maximum Conductor Temperature

    Maximum conductor temperature in normal use: 70°C

    Standard Compliance

    The use of the cable type 60227 IEC 01 comply with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6 7 8
    Number and nominal cross-sectional area of conductors
    mm²
    Class of conductor according to IEC 60228 Insulation thickness specified value
    mm
    Inner covering thickness approximate value
    mm
    Sheath thickness specified value
    mm
    Mean overall diameter Minimum insulation resistance at 70°C
    MΩ ·km
    Lower limit
    mm
    Upper limit
    mm
    2 × 1.5 1 0.7 0.4 1.2 7.6 10.0 0.011
    2 0.7 0.4 1.2 7.8 10.5 0.010
    2 × 2.5 1 0.8 0.4 1.2 8.6 11.5 0.010
    2 0.8 0.4 1.2 9.0 12.0 0.009
    2 × 4 1 0.8 0.4 1.2 9.6 12.5 0.00805
    2 0.8 0.4 1.2 10.0 13.0 0.00707
    2 × 6 1 0.8 0.4 1.2 10.5 13.5 0.00700
    2 0.8 0.4 1.2 11.0 14.0 0.00605
    2 × 10 1 1.0 0.6 1.4 13.0 16.5 0.00700
    2 1.0 0.6 1.4 13.5 17.5 0.00605
    2 × 16 2 1.0 0.6 1.4 15.5 20.0 0.00502
    2 × 25 2 1.2 0.8 1.4 18.5 24.0 0.00500
    2 × 35 2 1.2 1.0 1.6 21.0 27.5 0.00404
    3 × 1.5 1 0.7 0.4 1.2 8.0 10.5 0.011
    2 0.7 0.4 1.2 8.0 11.0 0.010
    3 × 2.5 1 0.8 0.4 1.2 9.2 12.0 0.010
    2 0.8 0.4 1.2 9.4 12.5 0.009
    3 × 4 1 0.8 0.4 1.2 10.0 13.0 0.00805
    2 0.8 0.4 1.2 10.5 13.5 0.00707
    3 × 6 1 0.8 0.4 1.4 11.5 14.5 0.00700
    2 0.8 0.4 1.4 12.0 15.5 0.00605
    3 × 10 1 1.0 0.6 1.4 14.0 17.5 0.00700
    2 1.0 0.6 1.4 14.5 19.0 0.00605
    3 × 16 2 1.0 0.8 1.4 16.5 21.5 0.00502
    3 × 25 2 1.2 0.8 1.6 20.5 26.0 0.00500
    3 × 35 2 1.2 1.0 1.6 22.0 29.0 0.00404
    4 × 1.5 1 0.7 0.4 1.2 8.6 11.5 0.011
    2 0.7 0.4 1.2 9.0 12.0 0.010
    4 × 2.5 1 0.8 0.4 1.2 10.0 13.0 0.010
    2 0.8 0.4 1.2 10.0 13.5 0.009
    4 × 4 1 0.8 0.4 1.4 11.5 14.5 0.00805
    2 0.8 0.4 1.4 12.0 15.0 0.00707
    4 × 6 1 0.8 0.6 1.4 12.5 16.0 0.00700
    2 0.8 0.6 1.4 13.0 17.0 0.00605
    4 × 10 1 1.0 0.6 1.4 15.5 19.0 0.00700
    2 1.0 0.6 1.4 16.0 20.5 0.00605
    4 × 16 2 1.0 0.8 1.4 18.0 23.5 0.00502
    4 × 25 2 1.2 1.0 1.6 22.5 28.5 0.00500
    4 × 35 2 1.2 1.0 1.6 24.5 32.0 0.00404
    5 × 1.5 1 0.7 0.4 1.2 9.4 12.0 0.011
    2 0.7 0.4 1.2 9.8 12.5 0.010
    5 × 2.5 1 0.8 0.4 1.2 11.0 14.0 0.010
    2 0.8 0.4 1.2 11.0 14.5 0.009
    5 × 4 1 0.8 0.6 1.4 12.5 16.0 0.00805
    2 0.8 0.6 1.4 13.0 17.0 0.00707
    5 × 6 1 0.8 0.6 1.4 13.5 17.5 0.00700
    2 0.8 0.6 1.4 14.5 18.5 0.00605
    5 × 10 1 1.0 0.6 1.4 17.0 21.0 0.00700
    2 1.0 0.6 1.4 17.5 22.0 0.00605
    5 × 16 2 1.0 0.8 1.6 20.5 26.0 0.00502
    5 × 25 2 1.2 1.0 1.6 24.5 31.5 0.00500
    5 × 35 2 1.2 1.2 1.6 27.0 35.0 0.00404

    Advantages

    (1) Consistent Product Quality

    We guarantee product excellence through a dual approach of premium material selection and precision manufacturing techniques. Our quality assurance protocol operates through four critical checkpoints:

    1. Initial material screening
    2. Production line quality control
    3. Intermediate product evaluation
    4. Final output verification

    To ensure complete accountability, we maintain:

    • Digital production records for every batch
    • Archived physical samples
    • Full supply chain traceability
    (2) Industry-Leading Delivery Speed

    Our supply chain is engineered for maximum responsiveness, featuring:

    • Strategic inventory management:
      • Finished goods stock
      • Semi-processed components reserve
    • Flexible production systems:
      • Rapid configuration changes
      • Dynamic capacity allocation

    This infrastructure enables us to:

    ✓ Process urgent orders within 24 hours

    ✓ Accommodate last-minute quantity changes

    ✓ Meet tight project deadlines

    (3) Tailored Customization Services

    For specialized product requirements, we offer:

    A dedicated project team including:

    • Design engineers
    • Manufacturing specialists
    • Quality assurance professionals
    • Customer service representatives

    Our proven development process:

    1. Requirements analysis
    2. Technical solution design
    3. Prototype validation
    4. Full-scale production
    5. Post-delivery support

    This comprehensive approach ensures customized solutions that precisely match your operational needs and performance criteria.

    Frequently Asked Questions

    What are the conductor options available for this cable?
    The cable is available with 2, 3, 4, or 5 conductors. The conductors comply with the requirements of IEC 60228, featuring Class 1 for solid conductors and Class 2 for stranded conductors.
    What materials are used for the insulation and sheath?
    The insulation is made of polyvinyl chloride (PVC) compound of type PVC/C applied around each core. The outer sheath consists of polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.
    What is the maximum operating temperature of the cable?
    The maximum conductor temperature under normal operating conditions is 70°C.
    Which standards apply to the safety and usage of these cables?
    The use of the cable type 60227 IEC 01 complies with the IEC 62440 standard, which provides comprehensive safety guidance for electric cables with a rated voltage not exceeding 450/750 V.
    How is the quality of the cable guaranteed?
    Quality is guaranteed through premium material selection, precision manufacturing, and a 4-step quality assurance protocol (initial screening, production line QC, intermediate evaluation, and final verification), backed by full supply chain traceability and archived physical samples.
    Do you support customized cable specifications?
    Yes, we offer tailored customization services. We assign a dedicated project team (consisting of design, manufacturing, QA, and service specialists) to handle your requirements through analysis, solution design, prototype validation, production, and post-delivery support.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*