Introducing our high-quality electrical cables, designated as Code 60227 IEC 10 and conforming to the IEC 60227-4 standards. These cables are designed to operate at a rated voltage of 300/500 V, ensuring reliable performance in various applications. As a leading supplier in China, our factory specializes in manufacturing durable and efficient electrical products that meet the highest industry standards. Trust our expertise and choose our cables for your next project to experience optimal safety and functionality

    Construction

    (1) Conductors

    Number of conductors: 2, 3, 4 or 5

    The conductors comply with the requirements of IEC 60228:

    • Class 1 for solid conductors
    • Class 2 for stranded conductors

    (2) Insulation

    The insulation is polyvinyl chloride compound of type PVC/C applied around each conductor.

    (3) Assembly of cores

    The cores are twisted together.

    (4) Inner Covering

    The twisted cores are covered by an extruded inner covering consisting of an unvulcanized rubber or plastic compound.

    It is possible to separate the cores easily.

    (5) Sheath

    The sheath is polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.

    The sheath fit closely and it is possible to remove it without damage to the inner covering.

    Technical Performance

    Operating Temperature

    Maximum conductor temperature in normal use: 70°C

    Standard Compliance & Rating

    The use of the cable type 60227 IEC 01 comply with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6 7 8
    Number and nominal cross-sectional area of conductors
    mm²
    Class of conductor according to IEC 60228 Insulation thickness specified value
    mm
    Inner covering thickness approximate value
    mm
    Sheath thickness specified value
    mm
    Mean overall diameter
    mm
    Minimum insulation resistance at 70°C
    MΩ ·km
    Lower limit Upper limit
    2 × 1.5 1 0.7 0.4 1.2 7.6 10.0 0.011
    2 0.7 0.4 1.2 7.8 10.5 0.010
    2 × 2.5 1 0.8 0.4 1.2 8.6 11.5 0.010
    2 0.8 0.4 1.2 9.0 12.0 0.009
    2 × 4 1 0.8 0.4 1.2 9.6 12.5 0.00805
    2 0.8 0.4 1.2 10.0 13.0 0.00707
    2 × 6 1 0.8 0.4 1.2 10.5 13.5 0.00700
    2 0.8 0.4 1.2 11.0 14.0 0.00605
    2 × 10 1 1.0 0.6 1.4 13.0 16.5 0.00700
    2 1.0 0.6 1.4 13.5 17.5 0.00605
    2 × 16 2 1.0 0.6 1.4 15.5 20.0 0.00502
    2 × 25 2 1.2 0.8 1.4 18.5 24.0 0.00500
    2 × 35 2 1.2 1.0 1.6 21.0 27.5 0.00404
    3 × 1.5 1 0.7 0.4 1.2 8.0 10.5 0.011
    2 0.7 0.4 1.2 8.0 11.0 0.010
    3 × 2.5 1 0.8 0.4 1.2 9.2 12.0 0.010
    2 0.8 0.4 1.2 9.4 12.5 0.009
    3 × 4 1 0.8 0.4 1.2 10.0 13.0 0.00805
    2 0.8 0.4 1.2 10.5 13.5 0.00707
    3 × 6 1 0.8 0.4 1.4 11.5 14.5 0.00700
    2 0.8 0.4 1.4 12.0 15.5 0.00605
    3 × 10 1 1.0 0.6 1.4 14.0 17.5 0.00700
    2 1.0 0.6 1.4 14.5 19.0 0.00605
    3 × 16 2 1.0 0.8 1.4 16.5 21.5 0.00502
    3 × 25 2 1.2 0.8 1.6 20.5 26.0 0.00500
    3 × 35 2 1.2 1.0 1.6 22.0 29.0 0.00404
    4 × 1.5 1 0.7 0.4 1.2 8.6 11.5 0.011
    2 0.7 0.4 1.2 9.0 12.0 0.010
    4 × 2.5 1 0.8 0.4 1.2 10.0 13.0 0.010
    2 0.8 0.4 1.2 10.0 13.5 0.009
    4 × 4 1 0.8 0.4 1.4 11.5 14.5 0.00805
    2 0.8 0.4 1.4 12.0 15.0 0.00707
    4 × 6 1 0.8 0.6 1.4 12.5 16.0 0.00700
    2 0.8 0.6 1.4 13.0 17.0 0.00605
    4 × 10 1 1.0 0.6 1.4 15.5 19.0 0.00700
    2 1.0 0.6 1.4 16.0 20.5 0.00605
    4 × 16 2 1.0 0.8 1.4 18.0 23.5 0.00502
    4 × 25 2 1.2 1.0 1.6 22.5 28.5 0.00500
    4 × 35 2 1.2 1.0 1.6 24.5 32.0 0.00404
    5 × 1.5 1 0.7 0.4 1.2 9.4 12.0 0.011
    2 0.7 0.4 1.2 9.8 12.5 0.010
    5 × 2.5 1 0.8 0.4 1.2 11.0 14.0 0.010
    2 0.8 0.4 1.2 11.0 14.5 0.009
    5 × 4 1 0.8 0.6 1.4 12.5 16.0 0.00805
    2 0.8 0.6 1.4 13.0 17.0 0.00707
    5 × 6 1 0.8 0.6 1.4 13.5 17.5 0.00700
    2 0.8 0.6 1.4 14.5 18.5 0.00605
    5 × 10 1 1.0 0.6 1.4 17.0 21.0 0.00700
    2 1.0 0.6 1.4 17.5 22.0 0.00605
    5 × 16 2 1.0 0.8 1.6 20.5 26.0 0.00502
    5 × 25 2 1.2 1.0 1.6 24.5 31.5 0.00500
    5 × 35 2 1.2 1.2 1.6 27.0 35.0 0.00404

    Advantages

    (1) Consistent Product Quality

    We guarantee product excellence through a dual approach of premium material selection and precision manufacturing techniques. Our quality assurance protocol operates through four critical checkpoints:

    • Initial material screening
    • Production line quality control
    • Intermediate product evaluation
    • Final output verification

    To ensure complete accountability, we maintain:

    • Digital production records for every batch
    • Archived physical samples
    • Full supply chain traceability

    (2) Industry-Leading Delivery Speed

    Our supply chain is engineered for maximum responsiveness, featuring:

    • Strategic inventory management:
      • Finished goods stock
      • Semi-processed components reserve
    • Flexible production systems:
      • Rapid configuration changes
      • Dynamic capacity allocation

    This infrastructure enables us to:

    • ✓ Process urgent orders within 24 hours
    • ✓ Accommodate last-minute quantity changes
    • ✓ Meet tight project deadlines

    (3) Tailored Customization Services

    For specialized product requirements, we offer a dedicated project team including:

    • Design engineers
    • Manufacturing specialists
    • Quality assurance professionals
    • Customer service representatives

    Our proven development process:

    • Requirements analysis
    • Technical solution design
    • Prototype validation
    • Full-scale production
    • Post-delivery support

    This comprehensive approach ensures customized solutions that precisely match your operational needs and performance criteria.

    Frequently Asked Questions (FAQ)

    What is the maximum conductor operating temperature for this cable?

    Under normal operating conditions, the maximum conductor temperature is 70°C in compliance with standard technical specifications.

    Which conductor types and standards are supported?

    The cable supports 2, 3, 4, or 5 conductors complying with IEC 60228 standards, available as Class 1 solid conductors or Class 2 stranded conductors.

    What materials are used for the insulation and outer sheath?

    Each conductor is insulated with a PVC/C compound, and the outer sheath consists of a PVC/ST4 compound designed to fit closely while allowing easy removal without damaging the inner covering.

    What voltage rating and standard guidelines apply to this cable?

    The cable complies with IEC 62440 (type 60227 IEC 01), which governs the safe operation of electric cables with rated voltages up to 450/750 V.

    How is the internal structure protected under the sheath?

    The twisted core assembly is protected by an extruded inner covering composed of unvulcanized rubber or plastic compound, designed to allow easy core separation.

    How does the quality assurance and order processing system work?

    Quality is maintained across 4 checkpoints (material screening, line QC, intermediate evaluation, final verification) backed by full batch traceability, while our dynamic inventory enables processing urgent orders within 24 hours.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*