Leave Your Message
China Suppliers IEC 60227 RVV Ordinary PVC Sheathed Cord 300/500V - Quality Cable Factory
Hot Products

China Suppliers IEC 60227 RVV Ordinary PVC Sheathed Cord 300/500V - Quality Cable Factory

Introducing our high-quality electrical cable, recognized by the code designation: 60227 IEC 5Manufactured in compliance with the stringent standards of IEC 60227-5, this cable is designed to deliver reliable performance for various applications. With a rated voltage of 300/500 V, our product ensures excellent conductivity and safety. As a leading supplier and factory based in China, we are committed to providing top-notch electrical solutions that meet international standards.

    Construction

    (1) Conductors

    Number of conductors: 2, 3, 4 or 5.

    The conductors comply with the requirements given in IEC 60228 for class 5 conductors.

    (2) Insulation

    The insulation is polyvinyl chloride compound of type PVC/D applied around each conductor.

    (3) Assembly of cores and fillers

    Circular cord: the cores and the fillers are twisted together.

    Flat cord: the cores are laid parallel.

    For a circular cord having two cores, the space between the cores is filled either by separate fillers or by the sheath filling the interstices. Any filler are not adhere to the cores.

    (4) Sheath

    The sheath is polyvinyl chloride compound of type PVC/ST5 applied around the cores.

    The sheath fill the spaces between the cores, thus forming a filling, but it is not adhere to the cores. The assembly of cores is surrounded by a separator, which is not adhere to the cores.

    The assembly of circular cords has a practically circular cross-section.

    Technical Performance

    Maximum conductor temperature in normal use: 70°C
    The use of the cable type 60227 IEC 53 comply with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6
    Number and nominal cross-
    sectional area
    of conductors
    mm²
    Thickness of
    insulation
    Thickness of sheath Mean overall
    dimensions
    Minimum
    insulation
    resistance at
    70°C
    MΩ ·km
    Specified value
    mm
    Specified value
    mm
    Lower limit
    mm
    Upper limit
    mm
    2 × 0.75 0.6 0.8 5.7
    or
    3.7 × 6.0
    7.2
    or
    4.5 × 7.2
    0.011
    2 × 1 0.6 0.8 5.9
    or
    3.9 × 6.2
    7.5
    or
    4.7 × 7.5
    0.010
    2 × 1.5 0.7 0.8 6.8 8.6 0.010
    2 × 2.5 0.8 1.0 8.4 10.6 0.009
    2 × 4 0.8 1.1 9.7 12.1 0.007
    3 × 0.75 0.6 0.8 6.0 7.6 0.011
    3 × 1 0.6 0.8 6.3 8.0 0.010
    3 × 1.5 0.7 0.9 7.4 9.4 0.010
    3 × 2.5 0.8 1.1 9.2 11.4 0.009
    3 × 4 0.8 1.1 10.3 12.8 0.007
    4 × 0.75 0.6 0.8 6.6 8.3 0.011
    4 × 1 0.6 0.9 7.1 9.0 0.010
    4 × 1.5 0.7 1.0 8.4 10.5 0.010
    4 × 2.5 0.8 1.1 10.1 12.5 0.009
    4 × 4 0.8 1.2 11.5 14.3 0.007
    5 × 0.75 0.6 0.9 7.4 9.3 0.011
    5 × 1 0.6 0.9 7.8 9.8 0.010
    5 × 1.5 0.7 1.1 9.3 11.6 0.010
    5 × 2.5 0.8 1.2 11.2 13.9 0.009
    5 × 4 0.8 1.3 12.8 15.9 0.007

    Advantages

    (1) Consistent Product Quality

    Our company utilizes high-quality raw materials and advanced manufacturing processes to ensure that the products meet customers' specifications and performance requirements. Supported by a comprehensive inspection system, we rigorously monitor quality from four key stages: raw material inspection, in-process inspection, semi-finished product inspection, and finished product inspection. Throughout production, we strictly implement data collection protocols and retain product samples, ensuring full traceability for every item.

    (2) Industry-Leading Delivery Speed

    We maintain ample inventory across all product categories, enabling us to promptly fulfill urgent customer demands. Additionally, our strategic stock of semi-finished products, combined with a highly flexible production management approach, allows us to efficiently address diverse and time-sensitive customer requirements.

    (3) Tailored Customization Services

    For customized product requests, we have established a sophisticated and streamlined workflow. Each custom project is supported by a dedicated one-on-one service team, comprising experts from R&D, sales, production, after-sales, and other relevant departments. This structure ensures professional and efficient solutions tailored to the customer's specific needs.

    Frequently Asked Questions

    What is the maximum operating temperature for 60227 IEC 53 cables?

    The maximum conductor temperature for the 60227 IEC 53 cable during normal use is 70°C.

    What standards do the cable conductors comply with?

    The conductors are designed to comply with all requirements specified in the IEC 60228 standard for Class 5 conductors.

    What insulation and sheath materials are used in these cables?

    The cable features a polyvinyl chloride insulation of type PVC/D applied around each conductor, and a protective polyvinyl chloride sheath of type PVC/ST5 applied around the assembled cores.

    How are the cores and fillers assembled for circular and flat cords?

    For circular cords, the cores and fillers are twisted together to maintain a practically circular cross-section. For flat cords, the cores are laid parallel. Fillers, when used, do not adhere to the cores.

    How does the quality control process ensure reliable products?

    Quality is maintained through a rigorous four-stage inspection system covering: raw materials, in-process production, semi-finished products, and finished products. Comprehensive data collection and sample retention ensure complete traceability.

    What customization services are available for special cable requirements?

    Custom projects are managed by a dedicated one-on-one team consisting of professionals from R&D, sales, production, and after-sales departments to deliver tailored technical solutions.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*