Leave Your Message
China Suppliers Factory for 60227 IEC 10 BVV Light PVC Sheathed Cable - Rated Voltage 300/500 V
Hot Products

China Suppliers Factory for 60227 IEC 10 BVV Light PVC Sheathed Cable - Rated Voltage 300/500 V

Introducing our high-quality electrical cable designed in accordance with the latest standards. The Code designation is 60227 IEC 10, and it complies with IEC 60227-4 standards. This cable is rated for a voltage of 300/500 V, making it ideal for various applications. As a leading supplier in China, we take pride in our advanced manufacturing processes at our state-of-the-art factory. Trust us for reliable and durable electrical solutions that meet your needs.

    Construction

    (1)

    Conductors

    Number of conductors: 2, 3, 4 or 5

    The conductors comply with the requirements of IEC 60228:

    • class 1 for solid conductors;

    • class 2 for stranded conductors.

    (2)

    Insulation

    The insulation is polyvinyl chloride compound of type PVC/C applied around each conductor.

    (3)

    Assembly of cores

    The cores are twisted together.

    (4)

    Inner covering

    The twisted cores are covered by an extruded inner covering consisting of an unvulcanized rubber or plastic compound.

    It is possible to separate the cores easily.

    (5)

    Sheath

    The sheath is polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.

    The sheath fit closely and it is possible to remove it without damage to the inner covering.

    Technical Performance

    Maximum conductor temperature in normal use: 70°C

    The use of the cable type 60227 IEC 01 comply with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6 7 8
    Number and nominal cross-sectional area of conductors
    mm²
    Class of conductor according to IEC 60228 Insulation thickness specified value
    mm
    Inner covering thickness approximate value
    mm
    Sheath thickness specified value
    mm
    Mean overall diameter Minimum insulation resistance at 70°C
    MΩ·km
    Lower limit
    mm
    Upper limit
    mm
    2 × 1.5 1 0.7 0.4 1.2 7.6 10.0 0.011
    2 0.7 0.4 1.2 7.8 10.5 0.010
    2 × 2.5 1 0.8 0.4 1.2 8.6 11.5 0.010
    2 0.8 0.4 1.2 9.0 12.0 0.009
    2 × 4 1 0.8 0.4 1.2 9.6 12.5 0.00805
    2 0.8 0.4 1.2 10.0 13.0 0.00707
    2 × 6 1 0.8 0.4 1.2 10.5 13.5 0.00700
    2 0.8 0.4 1.2 11.0 14.0 0.00605
    2 × 10 1 1.0 0.6 1.4 13.0 16.5 0.00700
    2 1.0 0.6 1.4 13.5 17.5 0.00605
    2 × 16 2 1.0 0.6 1.4 15.5 20.0 0.00502
    2 × 25 2 1.2 0.8 1.4 18.5 24.0 0.00500
    2 × 35 2 1.2 1.0 1.6 21.0 27.5 0.00404
    3 × 1.5 1 0.7 0.4 1.2 8.0 10.5 0.011
    2 0.7 0.4 1.2 8.0 11.0 0.010
    3 × 2.5 1 0.8 0.4 1.2 9.2 12.0 0.010
    2 0.8 0.4 1.2 9.4 12.5 0.009
    3 × 4 1 0.8 0.4 1.2 10.0 13.0 0.00805
    2 0.8 0.4 1.2 10.5 13.5 0.00707
    3 × 6 1 0.8 0.4 1.4 11.5 14.5 0.00700
    2 0.8 0.4 1.4 12.0 15.5 0.00605
    3 × 10 1 1.0 0.6 1.4 14.0 17.5 0.00700
    2 1.0 0.6 1.4 14.5 19.0 0.00605
    3 × 16 2 1.0 0.8 1.4 16.5 21.5 0.00502
    3 × 25 2 1.2 0.8 1.6 20.5 26.0 0.00500
    3 × 35 2 1.2 1.0 1.6 22.0 29.0 0.00404
    4 × 1.5 1 0.7 0.4 1.2 8.6 11.5 0.011
    2 0.7 0.4 1.2 9.0 12.0 0.010
    4 × 2.5 1 0.8 0.4 1.2 10.0 13.0 0.010
    2 0.8 0.4 1.2 10.0 13.5 0.009
    4 × 4 1 0.8 0.4 1.4 11.5 14.5 0.00805
    2 0.8 0.4 1.4 12.0 15.0 0.00707
    4 × 6 1 0.8 0.6 1.4 12.5 16.0 0.00700
    2 0.8 0.6 1.4 13.0 17.0 0.00605
    4 × 10 1 1.0 0.6 1.4 15.5 19.0 0.00700
    2 1.0 0.6 1.4 16.0 20.5 0.00605
    4 × 16 2 1.0 0.8 1.4 18.0 23.5 0.00502
    4 × 25 2 1.2 1.0 1.6 22.5 28.5 0.00500
    4 × 35 2 1.2 1.0 1.6 24.5 32.0 0.00404
    5 × 1.5 1 0.7 0.4 1.2 9.4 12.0 0.011
    2 0.7 0.4 1.2 9.8 12.5 0.010
    5 × 2.5 1 0.8 0.4 1.2 11.0 14.0 0.010
    2 0.8 0.4 1.2 11.0 14.5 0.009
    5 × 4 1 0.8 0.6 1.4 12.5 16.0 0.00805
    2 0.8 0.6 1.4 13.0 17.0 0.00707
    5 × 6 1 0.8 0.6 1.4 13.5 17.5 0.00700
    2 0.8 0.6 1.4 14.5 18.5 0.00605
    5 × 10 1 1.0 0.6 1.4 17.0 21.0 0.00700
    2 1.0 0.6 1.4 17.5 22.0 0.00605
    5 × 16 2 1.0 0.8 1.6 20.5 26.0 0.00502
    5 × 25 2 1.2 1.0 1.6 24.5 31.5 0.00500
    5 × 35 2 1.2 1.2 1.6 27.0 35.0 0.00404

    Advantages

    (1) Consistent Product Quality

    We guarantee product excellence through a dual approach of premium material selection and precision manufacturing techniques. Our quality assurance protocol operates through four critical checkpoints:

    1. Initial material screening
    2. Production line quality control
    3. Intermediate product evaluation
    4. Final output verification

    To ensure complete accountability, we maintain:

    • Digital production records for every batch
    • Archived physical samples
    • Full supply chain traceability

    (2) Industry-Leading Delivery Speed

    Our supply chain is engineered for maximum responsiveness, featuring:

    • Strategic inventory management:
      • Finished goods stock
      • Semi-processed components reserve
    • Flexible production systems:
      • Rapid configuration changes
      • Dynamic capacity allocation

    This infrastructure enables us to:

    • Process urgent orders within 24 hours
    • Accommodate last-minute quantity changes
    • Meet tight project deadlines

    (3) Tailored Customization Services

    For specialized product requirements, we offer:

    A dedicated project team including:

    • Design engineers
    • Manufacturing specialists
    • Quality assurance professionals
    • Customer service representatives

    Our proven development process:

    1. Requirements analysis
    2. Technical solution design
    3. Prototype validation
    4. Full-scale production
    5. Post-delivery support

    This comprehensive approach ensures customized solutions that precisely match your operational needs and performance criteria.

    Frequently Asked Questions

    What standards do the conductors comply with?
    The conductors comply with the requirements of IEC 60228, featuring class 1 for solid conductors and class 2 for stranded conductors.
    What materials are used for the insulation and sheath of this cable?
    The insulation is made of a polyvinyl chloride compound of type PVC/C, and the sheath is made of a polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.
    What is the maximum conductor temperature for safe operation?
    The maximum conductor temperature in normal use is 70°C. Additionally, the use of the cable type 60227 IEC 01 complies with IEC 62440 for rated voltages not exceeding 450/750 V.
    How does the manufacturer guarantee consistent product quality?
    Quality is guaranteed through premium material selection, precision manufacturing, and four critical checkpoints (material screening, production line QC, intermediate evaluation, and final verification), backed by digital records, physical samples, and full supply chain traceability.
    What customization services are available for specialized requirements?
    We offer tailored customization supported by a dedicated project team of design engineers, manufacturing specialists, QA professionals, and customer service representatives. The development process follows a proven 5-step path from requirements analysis to post-delivery support.
    How fast can urgent orders be delivered?
    Through strategic inventory management and flexible production systems, urgent orders can be processed within 24 hours, accommodating last-minute quantity changes and tight project deadlines.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*