Introducing our high-quality electrical cables designed to meet rigorous standards and specifications. Our products are identified by the code designation 60227 IEC 10 and comply with the IEC 60227-4 standard. With a rated voltage of 300/500 V, these cables are perfect for a wide range of applications. As a leading manufacturer in China, we pride ourselves on providing reliable and durable solutions. Partner with us as your preferred suppliers, backed by our state-of-the-art factory and commitment to excellence

    Construction

    1 Conductors

    Number of conductors: 2, 3, 4 or 5

    The conductors comply with the requirements of IEC 60228:

    - Class 1 for solid conductors;

    - Class 2 for stranded conductors.

    2 Insulation

    The insulation is polyvinyl chloride compound of type PVC/C applied around each conductor.

    3 Assembly of Cores

    The cores are twisted together.

    4 Inner Covering

    The twisted cores are covered by an extruded inner covering consisting of an unvulcanized rubber or plastic compound.

    It is possible to separate the cores easily.

    5 Sheath

    The sheath is polyvinyl chloride compound of type PVC/ST4 applied around the inner covering.

    The sheath fit closely and it is possible to remove it without damage to the inner covering.

    Technical Performance

    Maximum conductor temperature in normal use: 70°C
    The use of the cable type 60227 IEC 01 complies with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6 7 8
    Number and nominal cross-sectional area of conductors
    mm²
    Class of conductor according to IEC 60228 Insulation thickness specified value
    mm
    Inner covering thickness approximate value
    mm
    Sheath thickness specified value
    mm
    Mean overall diameter Minimum insulation resistance at 70°C
    MΩ ·km
    Lower limit
    mm
    Upper limit
    mm
    2 × 1.5 1 0.7 0.4 1.2 7.6 10.0 0.011
    2 0.7 0.4 1.2 7.8 10.5 0.010
    2 × 2.5 1 0.8 0.4 1.2 8.6 11.5 0.010
    2 0.8 0.4 1.2 9.0 12.0 0.009
    2 × 4 1 0.8 0.4 1.2 9.6 12.5 0.00805
    2 0.8 0.4 1.2 10.0 13.0 0.00707
    2 × 6 1 0.8 0.4 1.2 10.5 13.5 0.00700
    2 0.8 0.4 1.2 11.0 14.0 0.00605
    2 × 10 1 1.0 0.6 1.4 13.0 16.5 0.00700
    2 1.0 0.6 1.4 13.5 17.5 0.00605
    2 × 16 2 1.0 0.6 1.4 15.5 20.0 0.00502
    2 × 25 2 1.2 0.8 1.4 18.5 24.0 0.00500
    2 × 35 2 1.2 1.0 1.6 21.0 27.5 0.00404
    3 × 1.5 1 0.7 0.4 1.2 8.0 10.5 0.011
    2 0.7 0.4 1.2 8.0 11.0 0.010
    3 × 2.5 1 0.8 0.4 1.2 9.2 12.0 0.010
    2 0.8 0.4 1.2 9.4 12.5 0.009
    3 × 4 1 0.8 0.4 1.2 10.0 13.0 0.00805
    2 0.8 0.4 1.2 10.5 13.5 0.00707
    3 × 6 1 0.8 0.4 1.4 11.5 14.5 0.00700
    2 0.8 0.4 1.4 12.0 15.5 0.00605
    3 × 10 1 1.0 0.6 1.4 14.0 17.5 0.00700
    2 1.0 0.6 1.4 14.5 19.0 0.00605
    3 × 16 2 1.0 0.8 1.4 16.5 21.5 0.00502
    3 × 25 2 1.2 0.8 1.6 20.5 26.0 0.00500
    3 × 35 2 1.2 1.0 1.6 22.0 29.0 0.00404
    4 × 1.5 1 0.7 0.4 1.2 8.6 11.5 0.011
    2 0.7 0.4 1.2 9.0 12.0 0.010
    4 × 2.5 1 0.8 0.4 1.2 10.0 13.0 0.010
    2 0.8 0.4 1.2 10.0 13.5 0.009
    4 × 4 1 0.8 0.4 1.4 11.5 14.5 0.00805
    2 0.8 0.4 1.4 12.0 15.0 0.00707
    4 × 6 1 0.8 0.6 1.4 12.5 16.0 0.00700
    2 0.8 0.6 1.4 13.0 17.0 0.00605
    4 × 10 1 1.0 0.6 1.4 15.5 19.0 0.00700
    2 1.0 0.6 1.4 16.0 20.5 0.00605
    4 × 16 2 1.0 0.8 1.4 18.0 23.5 0.00502
    4 × 25 2 1.2 1.0 1.6 22.5 28.5 0.00500
    4 × 35 2 1.2 1.0 1.6 24.5 32.0 0.00404
    5 × 1.5 1 0.7 0.4 1.2 9.4 12.0 0.011
    2 0.7 0.4 1.2 9.8 12.5 0.010
    5 × 2.5 1 0.8 0.4 1.2 11.0 14.0 0.010
    2 0.8 0.4 1.2 11.0 14.5 0.009
    5 × 4 1 0.8 0.6 1.4 12.5 16.0 0.00805
    2 0.8 0.6 1.4 13.0 17.0 0.00707
    5 × 6 1 0.8 0.6 1.4 13.5 17.5 0.00700
    2 0.8 0.6 1.4 14.5 18.5 0.00605
    5 × 10 1 1.0 0.6 1.4 17.0 21.0 0.00700
    2 1.0 0.6 1.4 17.5 22.0 0.00605
    5 × 16 2 1.0 0.8 1.6 20.5 26.0 0.00502
    5 × 25 2 1.2 1.0 1.6 24.5 31.5 0.00500
    5 × 35 2 1.2 1.2 1.6 27.0 35.0 0.00404

    Advantages

    Consistent Product Quality

    We guarantee product excellence through a dual approach of premium material selection and precision manufacturing techniques. Our quality assurance protocol operates through four critical checkpoints:

    • Initial material screening
    • Production line quality control
    • Intermediate product evaluation
    • Final output verification

    To ensure complete accountability, we maintain:

    • Digital production records for every batch
    • Archived physical samples
    • Full supply chain traceability

    Industry-Leading Delivery Speed

    Our supply chain is engineered for maximum responsiveness, featuring:

    • Strategic inventory management:
      • Finished goods stock
      • Semi-processed components reserve
    • Flexible production systems:
      • Rapid configuration changes
      • Dynamic capacity allocation

    This infrastructure enables us to:

    • Process urgent orders within 24 hours
    • Accommodate last-minute quantity changes
    • Meet tight project deadlines

    Tailored Customization Services

    For specialized product requirements, we offer a dedicated project team including:

    • Design engineers
    • Manufacturing specialists
    • Quality assurance professionals
    • Customer service representatives

    Our proven development process:

    • 1. Requirements analysis
    • 2. Technical solution design
    • 3. Prototype validation
    • 4. Full-scale production
    • 5. Post-delivery support

    This comprehensive approach ensures customized solutions that precisely match your operational needs and performance criteria.

    Frequently Asked Questions

    What conductor standards and classes do these cables support?
    The conductors comply with the requirements of IEC 60228. They are available in Class 1 for solid conductors and Class 2 for stranded conductors.
    What materials are used for the cable insulation and sheath?
    The insulation is made of polyvinyl chloride compound type PVC/C, which is applied around each core. The outer sheath is made of polyvinyl chloride compound type PVC/ST4, applied over the inner covering.
    What is the maximum operating temperature of the cable?
    The maximum conductor temperature in normal use is 70°C.
    What voltage rating guidance does the 60227 IEC 01 cable comply with?
    It complies with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.
    How is consistent product quality guaranteed?
    Quality is guaranteed through premium material selection, precision manufacturing, and four critical checkpoints: initial material screening, production line QC, intermediate product evaluation, and final output verification. We also maintain digital production records, physical samples, and full supply chain traceability.
    What does the customization process involve?
    Our customization service features a dedicated project team (design, manufacturing, QA, and customer service) that follows a 5-step process: requirements analysis, technical solution design, prototype validation, full-scale production, and post-delivery support.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*