Leave Your Message
60227 IEC 53 RVV PVC Sheathed Cord - China Suppliers & Factory, Rated Voltage 300/500V
Hot Products

60227 IEC 53 RVV PVC Sheathed Cord - China Suppliers & Factory, Rated Voltage 300/500V

Introducing our premium electrical wire designated as Code 60227 IEC 53, compliant with IEC 60227-5 standards. This high-quality wire is rated for 300/500 V, ensuring reliability and safety for various electrical applications. As a leading supplier in China, our factory guarantees top-notch manufacturing processes to deliver exceptional performance and durability. Choose our products for your electrical needs and experience the excellence of Chinese craftsmanship.

    Construction

    (1) Conductors

    Number of conductors: 2, 3, 4 or 5.

    The conductors comply with the requirements given in IEC 60228 for class 5 conductors.

    (2) Insulation

    The insulation is polyvinyl chloride compound of type PVC/D applied around each conductor.

    (3) Assembly of cores and fillers

    Circular cord: the cores and the fillers are twisted together.

    Flat cord: the cores are laid parallel.

    For a circular cord having two cores, the space between the cores is filled either by separate fillers or by the sheath filling the interstices. Any filler are not adhere to the cores.

    (4) Sheath

    The sheath is polyvinyl chloride compound of type PVC/ST5 applied around the cores.

    The sheath fills the spaces between the cores, forming a filling without adhering to the cores. The assembly of cores is surrounded by a separator, which is not adhere to the cores.

    The assembly of circular cords has a practically circular cross-section.

    Technical Performance

    Maximum conductor temperature in normal use: 70°C
    The use of the cable type 60227 IEC 53 complies with IEC 62440, which provides guidance on the safe use of electric cables with a rated voltage not exceeding 450/750 V.

    Parameter Table

    1 2 3 4 5 6
    Number and nominal cross-sectional area of conductors
    mm²
    Thickness of insulation Thickness of sheath Mean overall dimensions Minimum insulation resistance at 70°C
    MΩ ·km
    Specified value
    mm
    Specified value
    mm
    Lower limit
    mm
    Upper limit
    mm
    2 × 0.75 0.6 0.8 5.7
    or
    3.7 × 6.0
    7.2
    or
    4.5 × 7.2
    0.011
    2 × 1 0.6 0.8 5.9
    or
    3.9 × 6.2
    7.5
    or
    4.7 × 7.5
    0.010
    2 × 1.5 0.7 0.8 6.8 8.6 0.010
    2 × 2.5 0.8 1.0 8.4 10.6 0.009
    2 × 4 0.8 1.1 9.7 12.1 0.007
    3 × 0.75 0.6 0.8 6.0 7.6 0.011
    3 × 1 0.6 0.8 6.3 8.0 0.010
    3 × 1.5 0.7 0.9 7.4 9.4 0.010
    3 × 2.5 0.8 1.1 9.2 11.4 0.009
    3 × 4 0.8 1.1 10.3 12.8 0.007
    4 × 0.75 0.6 0.8 6.6 8.3 0.011
    4 × 1 0.6 0.9 7.1 9.0 0.010
    4 × 1.5 0.7 1.0 8.4 10.5 0.010
    4 × 2.5 0.8 1.1 10.1 12.5 0.009
    4 × 4 0.8 1.2 11.5 14.3 0.007
    5 × 0.75 0.6 0.9 7.4 9.3 0.011
    5 × 1 0.6 0.9 7.8 9.8 0.010
    5 × 1.5 0.7 1.1 9.3 11.6 0.010
    5 × 2.5 0.8 1.2 11.2 13.9 0.009
    5 × 4 0.8 1.3 12.8 15.9 0.007

    Advantages

    (1) Consistent Product Quality

    Our company utilizes high-quality raw materials and advanced manufacturing processes to ensure that the products meet customers' specifications and performance requirements. Supported by a comprehensive inspection system, we rigorously monitor quality from four key stages: raw material inspection, in-process inspection, semi-finished product inspection, and finished product inspection. Throughout production, we strictly implement data collection protocols and retain product samples, ensuring full traceability for every item.

    (2) Industry-Leading Delivery Speed

    We maintain ample inventory across all product categories, enabling us to promptly fulfill urgent customer demands. Additionally, our strategic stock of semi-finished products, combined with a highly flexible production management approach, allows us to efficiently address diverse and time-sensitive customer requirements.

    (3) Tailored Customization Services

    For customized product requests, we have established a sophisticated and streamlined workflow. Each custom project is supported by a dedicated one-on-one service team, comprising experts from R&D, sales, production, after-sales, and other relevant departments. This structure ensures professional and efficient solutions tailored to the customer's specific needs.

    Frequently Asked Questions (FAQ)

    What are the conductor specifications for the 60227 IEC 53 cable?
    The cable supports 2, 3, 4, or 5 conductors. These conductors comply strictly with the requirements of the IEC 60228 standard for Class 5 conductors, ensuring flexibility and reliable conductivity.
    What materials are used for the insulation and sheath?
    The insulation is made of a polyvinyl chloride compound of type PVC/D applied around each conductor. The outer sheath is composed of a PVC/ST5 compound, which fills the spaces between the cores without adhering to them.
    What is the difference in core assembly between circular and flat cords?
    For circular cords, the cores and fillers are twisted together to form a practically circular cross-section. For flat cords, the cores are laid parallel to each other.
    What is the maximum operating temperature and rated voltage for this cable?
    The maximum conductor temperature during normal use is 70°C. The cable type 60227 IEC 53 complies with safe use guidelines under IEC 62440 for rated voltages not exceeding 450/750 V.
    How is the consistent quality of your cables guaranteed?
    We monitor quality through a strict four-stage inspection system: raw materials, in-process, semi-finished, and finished product inspections. We implement rigorous data collection and sample retention to guarantee full traceability.
    Do you offer customization services for specialized requirements?
    Yes, we offer tailored customization services. Each project is handled by a dedicated one-on-one team representing R&D, sales, production, and after-sales departments to deliver optimized solutions.

    Leave Us A Message

    Your Name*

    Phone Number

    Message*